INSTALLATION
3-6 01 Jan 14
DE-7200VFDCentrifuge
EQUIPMENT HANDLING (CONT’D)
Figure 3-3. DE-7200 Control Cabinet Lifting Arrangement
EQUIPMENT POSITIONING AND MOUNTING
Base plates are required when installing the centrifuge. Lay out the installation site and locate the
base plates in accordance with Figure 3-4. The base plates have 1-9/16” x 1-9/16” (40mm x
40mm) centering posts. They may be either bolted or welded to the mounting platform to properly
position and prevent movement of the centrifuge. When lowering the centrifuge onto the base
plates, ensure that the centering posts engage with the opening at the bottom of each vibration
isolator (Figure 3-5).