MAINTENANCE
5-12 31 Dec 13
DE-7200VFDCentrifuge
Rotating Assembly Removal (Cont’d)
Figure 5-4. Conveyor Torque Limiter Clutch
6. Loosen nuts securing bowl drive motor to base, turn tensioning bolt to release tension, and
remove belts from bowl sheave.
7. Remove liquid and solid end temperature sensors (Figure 5-5) from main bearing pillow
blocks.
Figure 5-5. Solid End Temperature and Speed Sensors
8. Disconnect speed sensor cable from speed sensor.
9. Remove bolts and Belleville washers securing pillow blocks to base at liquid and solid ends
(Figure 5-6), and remove alignment pins from pillow blocks.